The saved wire color is detected continuously. A color match is shown in light green.
If the wire is inside the blue circle, its width does not exceed Wire diameter, and its length is at least Wire min length, it is shown in bright green.
2
Confirm two yellow crossings
The same valid wire must cross the yellow circular contour in two separate places.
Both crossings must remain detected continuously for the full Minimum detection time.
3
Wait until the wire leaves
After the two crossings are confirmed, the yellow contour must become completely free of the detected wire.
It must stay free continuously for the full Minimum detection time. If the wire appears on the yellow contour again before that time expires, the clear timer starts over.
4
Count one turn
When the yellow contour has stayed free for the full detection time, the counter increases by one.
The counting state resets immediately and the program is ready for the next cycle.
Only this sequence controls automatic turn counting:
valid wire → two yellow crossings → detection time → yellow clear → detection time → +1 → new cycle.